- Manufacturer Part Number : ADM3051CRZ
- Manufacturer : AD
- Description : High Speed Industrial CAN Transceiver with Bus Protection for 24 V Systems IC
- Series : ADM3051
- Reference Price : USD 0.72
- Our Price : We have a better price, contact us by email
- Product Type : Automotive Interfaces (CAN, Audio)
- Function : Non-Isolated Controller Area Network (CAN)
- Current Suggest : Production
- Status : Production
- ROHS Status : ROHS Compliant (Lead Free)
- Package Type : 8-Lead SOIC
- Pins : 8
- MFG Package Case : R-8
- Part Type : OTH
- Standard Packing Type : Tube
- Standard Packing Quantity : 98
- Working Temperature : -40 to 125C
- Other Part Number : ADM3051CRZ
- Shipping methods : DHL FEDEX UPS TNT
- Delivery Time : Ship within 1 day.
- Manufacturer Production time : 6-8 weeks (Normally have stocks)
- Weight : 0.001KG
Contact us to check the best price and real time inventory quantity for ADM3051CRZ. If you need any more information about ADM3051CRZ, you can also send us by email. Our email is [email protected], we will reply you in 12 hours.
- Physical layer CAN transceiver
- 5 V operation on VCC
- Complies with ISO 11898 standard
- High speed data rates up to
1 Mbps - Short-circuit protection on CANH and CANL against shorts to power/ground in 24 V systems
- Unpowered nodes do not disturb the bus
- Connect 110 or more nodes on the bus
- Slope control for reduced EMI
- Thermal shutdown protection
- Low current standby mode
- Industrial operating temperature range (−40°C to +125°C)
- Available in 8-lead SOIC package
The device has current-limiting and thermal shutdown featuresto protect against output short circuits and situations where thebus may be shorted to ground or power terminals in 24 V buspower systems. The part is fully specified over the industrialtemperature range of −40°C to +125°C and is available in an8-lead SOIC package.
Three operating modes are available: high speed, slope control,and standby. Pin 8 (RS) is used to select the operating mode.The low current standby mode can be selected by applying alogic high to RS.
The device can be set to operate with slope control to limit EMIby connecting RS with a resistor to ground to modify the riseand fall of slopes. This mode facilitates the use of unshieldedcables. Alternatively, disabling slope control by connecting RSto ground allows high speed operation. Shielded cables or othermeasures to control EMI are necessary in this mode.
APPLICATIONS
- CAN data buses
- Industrial field networks
- DeviceNet applications
- CanOpen, CanKingdom
At least one model within this product family is in production and available for purchase. The product is appropriate for new designs but newer alternatives may exist.