- Manufacturer Part Number : LTC4368HMS-2#WPBF
- Manufacturer : AD
- Description : 100V UV/OV and Reverse Protection Controller with Bidirectional Circuit Breaker IC
- Series : LTC4368
- Reference Price : USD 2.264
- Our Price : We have a better price, contact us by email
- Product Type : Surge Stopper, Overvoltage & Overcurrent Protection
- Function : -
- Current Suggest : Recommended for New Designs
- Status : Production
- ROHS Status : ROHS Compliant (Lead Free)
- Package Type : 10-Lead MSOP
- Pins : 10
- MFG Package Case : 05-08-1661
- Part Type : OTH
- Standard Packing Type : Tube
- Standard Packing Quantity : 50
- Working Temperature : -40 to 125C
- Other Part Number : LTC4368HMS-2#WPBF
- Shipping methods : DHL FEDEX UPS TNT
- Delivery Time : Ship within 1 day.
- Manufacturer Production time : 6-8 weeks (Normally have stocks)
- Weight : 0.001KG
Contact us to check the best price and real time inventory quantity for LTC4368HMS-2#WPBF. If you need any more information about LTC4368HMS-2#WPBF, you can also send us by email. Our email is [email protected], we will reply you in 12 hours.
- Wide Operating Voltage Range: 2.5V to 60V
- Overvoltage Protection to 100V
- Reverse Supply Protection to –40V
- Bidirectional Electronic Circuit Breaker:
- +50mV Forward Sense Threshold
- –50mV Reverse (LTC4368-1)
- –3mV Reverse (LTC4368-2)
- Adjustable ±1.5% Undervoltage and Overvoltage Thresholds
- Low Operating Current: 80µA
- Low Shutdown Current: 5µA
- Controls Back-to-Back N-Channel MOSFETs
- Blocks 50Hz and 60Hz AC Power
- Hot Swappable Supply Input
- Pin-Selectable Overcurrent Auto-Retry Timer or Latchoff
- 10-Pin MSOP and 3mm × 3mm DFN Packages
- AEC-Q100 Qualified for Automotive Applications
The LTC4368 protects applications from power supply voltages that may be too high, too low, or even negative and from overcurrent faults in both forward and reverse directions. The LTC4368 controls the gate voltage of a pair of external N-channel MOSFETs to ensure that the load is connected to the input supply only when there are no voltage or current faults.
Two comparator inputs allow configuration of the overvoltage (OV) and undervoltage (UV) set points using an external resistive divider. A current sense resistor sets the forward and reverse circuit breaker current thresholds. After a forward current fault, the LTC4368 will either latchoff power, or retry after a user adjustable delay. After a reverse current fault, the LTC4368 waits for the output to fall 100mV below the input to reconnect power to the load.
The LTC4368 has a 32ms turn-on delay that debounces live supply input connections and blocks 50Hz and 60Hz AC power. UV/OV faults also trigger the 32ms recovery delay before the external MOSFETs are turned back on.
Applications
- Reverse Battery Protection
- Portable Instrumentation
- Automotive and Industrial Surge Protection
- Energy Storage Systems
This product has been released to the market. The data sheet contains all final specifications and operating conditions. For new designs, ADI recommends utilization of these products.